The FHIR profiles used for the Observations Bundle
Heading Description
The record of physiological observations, e.g., weight, height, heart rate, blood pressure, temperature, pulse, respiratory rate and oxygen saturation. Use of National Early Warning Score (NEWS) scores where appropriate.
Mapping for Blood Pressure Observation
> | Level 1 | List Resource | > | Level 2 | CareConnect-Observation-1 Profile | > | Level 3 | CareConnect-BloodPressure-Observation-1 Profile |
View Used FHIR Elements | View All FHIR Elements |
Name | Card. | Conformance | Type | Description, Constraints and mapping for Digital Maternity Implementation | |||
---|---|---|---|---|---|---|---|
- id | 0..1 | Optional | Id | Logical id of this artifact | |||
- meta | 0..1 | Mandatory | Meta | Metadata about the resource The value attribute of the profile element MUST contain the value 'https://fhir.nhs.uk/STU3/StructureDefinition/CareConnect-BloodPressure-Observation-1' |
|||
- implicitRules | 0..1 | Not Used | Uri | A set of rules under which this content was created | |||
- language | 0..1 | Not Used | Code | Language of the resource content Binding (extensible): A human language. Common Languages |
|||
- text | 0..1 | Not Used | Narrative | Text summary of the resource, for human interpretation | |||
- contained | 0..* | Not Used | Resource | Contained, inline Resources | |||
- modifierExtension | 0..* | Not Used | Extension | Extensions that cannot be ignored Constraint (ext-1): Must have either extensions or value[x], not both Slicing: Description: Extensions are always sliced by (at least) url, Discriminator: url, Ordering: false, Rules: Open |
|||
- identifier | 0..* | Required | Identifier | Business Identifier for observation An identifier for this Observation |
|||
- - use | 0..1 | Not Used | Code | usual : official : temp : secondary (If known) Binding (required): Identifies the purpose for this identifier, if known. IdentifierUse |
|||
- - type | 0..1 | Not Used | CodeableConcept | Description of identifier Binding (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes |
|||
- - - coding | 0..* | Not Used | Coding | Code defined by a terminology system | |||
- - - - system | 0..1 | Not Used | Uri | Identity of the terminology system | |||
- - - - version | 0..1 | Not Used | String | Version of the system - if relevant | |||
- - - - code | 0..1 | Not Used | Code | Symbol in syntax defined by the system | |||
- - - - display | 0..1 | Not Used | String | Representation defined by the system | |||
- - - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- - system | 1..1 | Required | Uri | The namespace for the identifier value | |||
- - value | 1..1 | Mandatory | String | The value that is unique | |||
- - period | 0..1 | Not Used | Period | Time period when id is/was valid for use Constraint (per-1): If present, start SHALL have a lower value than end |
|||
- - - start | 0..1 | Not Used | dateTime | Starting time with inclusive boundary | |||
- - - end | 0..1 | Not Used | dateTime | End time with inclusive boundary, if not ongoing | |||
- - assigner | 0..1 | Required | Reference | Organization that issued id (may be just text) Constraint (ref-1): SHALL have a contained resource if a local reference is provided |
|||
Not Used | CareConnect-Organization-1 | ||||||
- - - reference | 0..1 | Not Used | String | Literal reference, Relative, internal or absolute URL | |||
- - - identifier | 0..1 | Not Used | Identifier | Logical reference, when literal reference is not known | |||
- - - display | 0..1 | Required | String | Text alternative for the resource | |||
- basedOn | 0..* | Not Used | Reference | Fulfills plan, proposal or order. Constraint (ref-1): SHALL have a contained resource if a local reference is provided |
|||
Not Used | CarePlan | ||||||
Not Used | DeviceRequest | ||||||
Not Used | ImmunizationRecommendation | ||||||
Not Used | NutritionOrder | ||||||
Not Used | ProcedureRequest | ||||||
Not Used | ReferralRequest | ||||||
Not Used | CareConnect-MedicationRequest-1 | ||||||
- - reference | 0..1 | Not Used | String | Literal reference, Relative, internal or absolute URL | |||
- - identifier | 0..1 | Not Used | Identifier | Logical reference, when literal reference is not known | |||
- - display | 0..1 | Not Used | String | Text alternative for the resource | |||
- status | 1..1 | Mandatory | Code | registered : preliminary : final : amended + Binding (required): Codes providing the status of an observation. ObservationStatus |
|||
- category | 0..* | Not Used | CodeableConcept | Classification of type of observation Binding (preferred): Codes for high level observation categories. Observation Category Codes The category MAY be used to define the nature of the observation being performed</font> |
|||
- - coding | 0..* | Not Used | Coding | Code defined by a terminology system | |||
- - - system | 0..1 | Not Used | Uri | Identity of the terminology system | |||
- - - version | 0..1 | Not Used | String | Version of the system - if relevant | |||
- - - code | 0..1 | Not Used | Code | Symbol in syntax defined by the system Code MUST be from one of the valueset https://fhir.hl7.org.uk/ValueSet/CareConnect-ScanCategory-1 |
|||
- - - display | 0..1 | Not Used | String | Representation defined by the system MUST be from one of the valueset https://fhir.hl7.org.uk/ValueSet/CareConnect-ScanCategory-1 and relate to code used in observation.code |
|||
- - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- code | 1..1 | Mandatory | CodeableConcept | Type of observation (code / type) Type of Observation performed |
|||
- - coding | 0..* | Mandatory | Coding | Code defined by a terminology system Slicing: Discriminator: code, Ordering: false, Rules: Open |
|||
- - coding (snomedCT) | 0..1 | Required | Coding | Code defined by a terminology system Binding (extensible): A code from the SNOMED Clinical Terminology UK coding system describing a type of observation CareConnect-ObservationType-1 |
|||
- - - extension (snomedCTDescriptionID) | 0..1 | Required | Extension-coding-sctdescid | The SNOMED CT Description ID for the display. Constraint (ext-1): Must have either extensions or value[x], not both |
|||
- - - system | 1..1 | Mandatory | Uri | Identity of the terminology system The element MUST contain the value 'http://snomed.info/sct' |
|||
- - - code | 1..1 | Mandatory | Code | Symbol in syntax defined by the system MUSt contain code '75367002' |
|||
- - - display | 1..1 | Mandatory | String | Representation defined by the system MUST be 'Blood pressure' |
|||
- - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - text | 0..1 | Optional | String | Plain text representation of the concept | |||
- subject | 0..1 | Mandatory | Reference | Who and/or what this is about Constraint (ref-1): SHALL have a contained resource if a local reference is provided |
|||
Not Used | Group | ||||||
Not Used | Device | ||||||
Mandatory | CareConnect-Patient-1 | ||||||
Not Used | CareConnect-Location-1 | ||||||
- - reference | 0..1 | Not Used | String | Literal reference, Relative, internal or absolute URL | |||
- - identifier | 0..1 | Mandatory | Identifier | Logical reference, when literal reference is not known | |||
- - display | 0..1 | Not Used | String | Text alternative for the resource | |||
- context | 0..1 | Not Used | Reference | Healthcare event during which this observation is made Constraint (ref-1): SHALL have a contained resource if a local reference is provided |
|||
Not Used | EpisodeOfCare | ||||||
Not Used | CareConnect-Encounter-1 | ||||||
- - reference | 0..1 | Not Used | String | Literal reference, Relative, internal or absolute URL | |||
- - identifier | 0..1 | Not Used | Identifier | Logical reference, when literal reference is not known | |||
- - display | 0..1 | Not Used | String | Text alternative for the resource | |||
- effective[x] | 0..1 | Required | dateTime | Clinically relevant time/time-period for observation The date on which the observation was recorded |
|||
Not Used | Period | ||||||
- issued | 0..1 | Not Used | Instant | Date/Time this was made available | |||
- performer | 0..* | Required | Reference | Who is responsible for the observation Constraint (ref-1): SHALL have a contained resource if a local reference is provided Name of the professional performing the observation |
|||
Not Used | RelatedPerson | ||||||
Not Used | CareConnect-Patient-1 | ||||||
Not Used | CareConnect-Organization-1 | The Site Code of where the safeguarding issue was recorded | |||||
Required | CareConnect-Practitioner-1 | Name of Professional recording the observation | |||||
- - reference | 0..1 | Not Used | String | Literal reference, Relative, internal or absolute URL | |||
- - identifier | 0..1 | Not Used | Identifier | Logical reference, when literal reference is not known | |||
- - display | 0..1 | Not Used | String | Text alternative for the resource | |||
- value[x] | 0..1 | Not Used | CodeableConcept | Actual result Constraint (qty-3): If a code for the unit is present, the system SHALL also be present The type of safeguarding risk recorded. 404684003 |Clinical finding (finding) OR |999002381000000108 OR \ |
Safeguarding issues simple reference set (foundation metadata concept)</font> Where no SNOMED CT code is available, coding.text MUST be used. |
||
Not Used | String | ||||||
Not Used | Quantity | ||||||
Not Used | Boolean | ||||||
Not Used | Range | ||||||
Not Used | Ratio | ||||||
Not Used | SampledData | ||||||
Not Used | Attachment | ||||||
Not Used | Time | ||||||
Not Used | dateTime | ||||||
Not Used | Period | ||||||
- dataAbsentReason | 0..1 | Not Used | CodeableConcept | Why the result is missing Binding (extensible): Codes specifying why the result (Observation.value[x]) is missing. Observation Value Absent Reason |
|||
- - coding | 0..* | Not Used | Coding | Code defined by a terminology system | |||
- - - system | 0..1 | Not Used | Uri | Identity of the terminology system | |||
- - - version | 0..1 | Not Used | String | Version of the system - if relevant | |||
- - - code | 0..1 | Not Used | Code | Symbol in syntax defined by the system | |||
- - - display | 0..1 | Not Used | String | Representation defined by the system | |||
- - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- interpretation | 0..1 | Not Used | CodeableConcept | High, low, normal, etc. Binding (extensible): Codes identifying interpretations of observations. Observation Interpretation Codes |
|||
- - coding | 0..* | Not Used | Coding | Code defined by a terminology system | |||
- - - system | 0..1 | Not Used | Uri | Identity of the terminology system | |||
- - - version | 0..1 | Not Used | String | Version of the system - if relevant | |||
- - - code | 0..1 | Not Used | Code | Symbol in syntax defined by the system | |||
- - - display | 0..1 | Not Used | String | Representation defined by the system | |||
- - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- comment | 0..1 | Not Used | String | Comments about result | |||
- bodySite | 0..1 | Not Used | CodeableConcept | Observed body part Binding (example): Codes describing anatomical locations. May include laterality. SNOMED CT Body Structures |
|||
- - coding | 0..* | Not Used | Coding | Code defined by a terminology system Slicing: Discriminator: code, Ordering: false, Rules: Open |
|||
- - coding (snomedCT) | 0..1 | Not Used | Coding | Code defined by a terminology system | |||
- - - extension (snomedCTDescriptionID) | 0..1 | Not Used | Extension-coding-sctdescid | The SNOMED CT Description ID for the display. Constraint (ext-1): Must have either extensions or value[x], not both |
|||
- - - system | 1..1 | Not Used | Uri | Identity of the terminology system The element MUST contain the value 'http://snomed.info/sct' |
|||
- - - code | 1..1 | Not Used | Code | Symbol in syntax defined by the system | |||
- - - display | 1..1 | Not Used | String | Representation defined by the system | |||
- - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- method | 0..1 | Not Used | CodeableConcept | How it was done Binding (example): Methods for simple observations. Observation Methods |
|||
- - coding | 0..* | Not Used | Coding | Code defined by a terminology system Slicing: Discriminator: code, Ordering: false, Rules: Open |
|||
- - coding (snomedCT) | 0..1 | Not Used | Coding | Code defined by a terminology system Binding (preferred): A code from SNOMED Clinical Terminology UK CareConnect-ObservationMethod-1 |
|||
- - - extension (snomedCTDescriptionID) | 0..1 | Not Used | Extension-coding-sctdescid | The SNOMED CT Description ID for the display. Constraint (ext-1): Must have either extensions or value[x], not both |
|||
- - - system | 1..1 | Not Used | Uri | Identity of the terminology system The element MUST contain the value 'http://snomed.info/sct' |
|||
- - - code | 1..1 | Not Used | Code | Symbol in syntax defined by the system | |||
- - - display | 1..1 | Not Used | String | Representation defined by the system | |||
- - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- specimen | 0..1 | Not Used | Reference | Specimen used for this observation Constraint (ref-1): SHALL have a contained resource if a local reference is provided |
|||
Not Used | Specimen | ||||||
- - reference | 0..1 | Not Used | String | Literal reference, Relative, internal or absolute URL | |||
- - identifier | 0..1 | Not Used | Identifier | Logical reference, when literal reference is not known | |||
- - display | 0..1 | Not Used | String | Text alternative for the resource | |||
- device | 0..1 | Not Used | Reference | (Measurement) Device Constraint (ref-1): SHALL have a contained resource if a local reference is provided |
|||
Not Used | Device | ||||||
Not Used | DeviceMetric | ||||||
- - reference | 0..1 | Not Used | String | Literal reference, Relative, internal or absolute URL | |||
- - identifier | 0..1 | Not Used | Identifier | Logical reference, when literal reference is not known | |||
- - display | 0..1 | Not Used | String | Text alternative for the resource | |||
- referenceRange | 0..* | Not Used | BackboneElement | Provides guide for interpretation Constraint (obs-3): Must have at least a low or a high or text |
|||
- - modifierExtension | 0..* | Not Used | Extension | Extensions that cannot be ignored Constraint (ext-1): Must have either extensions or value[x], not both |
|||
- - low | 0..1 | Not Used | Quantity ( SimpleQuantity ) | Low Range, if relevant Constraint (qty-3): If a code for the unit is present, the system SHALL also be present Constraint (sqty-1): The comparator is not used on a SimpleQuantity |
|||
- - - value | 0..1 | Not Used | Decimal | Numerical value (with implicit precision) | |||
- - - unit | 0..1 | Not Used | String | Unit representation | |||
- - - system | 0..1 | Not Used | Uri | System that defines coded unit form | |||
- - - code | 0..1 | Not Used | Code | Coded form of the unit | |||
- - high | 0..1 | Not Used | Quantity ( SimpleQuantity ) | High Range, if relevant Constraint (qty-3): If a code for the unit is present, the system SHALL also be present Constraint (sqty-1): The comparator is not used on a SimpleQuantity |
|||
- - - value | 0..1 | Not Used | Decimal | Numerical value (with implicit precision) | |||
- - - unit | 0..1 | Not Used | String | Unit representation | |||
- - - system | 0..1 | Not Used | Uri | System that defines coded unit form | |||
- - - code | 0..1 | Not Used | Code | Coded form of the unit | |||
- - type | 0..1 | Not Used | CodeableConcept | Reference range qualifier Binding (extensible): Code for the meaning of a reference range. Observation Reference Range Meaning Codes |
|||
- - - coding | 0..* | Not Used | Coding | Code defined by a terminology system | |||
- - - - system | 0..1 | Not Used | Uri | Identity of the terminology system | |||
- - - - version | 0..1 | Not Used | String | Version of the system - if relevant | |||
- - - - code | 0..1 | Not Used | Code | Symbol in syntax defined by the system | |||
- - - - display | 0..1 | Not Used | String | Representation defined by the system | |||
- - - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- - appliesTo | 0..* | Not Used | CodeableConcept | Reference range population Binding (example): Codes identifying the population the reference range applies to. Observation Reference Range Applies To Codes |
|||
- - - coding | 0..* | Not Used | Coding | Code defined by a terminology system | |||
- - - - system | 0..1 | Not Used | Uri | Identity of the terminology system | |||
- - - - version | 0..1 | Not Used | String | Version of the system - if relevant | |||
- - - - code | 0..1 | Not Used | Code | Symbol in syntax defined by the system | |||
- - - - display | 0..1 | Not Used | String | Representation defined by the system | |||
- - - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- - age | 0..1 | Not Used | Range | Applicable age range, if relevant Constraint (rng-2): If present, low SHALL have a lower value than high |
|||
- - - low | 0..1 | Not Used | Quantity ( SimpleQuantity ) | Low limit Constraint (qty-3): If a code for the unit is present, the system SHALL also be present Constraint (sqty-1): The comparator is not used on a SimpleQuantity |
|||
- - - - value | 0..1 | Not Used | Decimal | Numerical value (with implicit precision) | |||
- - - - unit | 0..1 | Not Used | String | Unit representation | |||
- - - - system | 0..1 | Not Used | Uri | System that defines coded unit form | |||
- - - - code | 0..1 | Not Used | Code | Coded form of the unit | |||
- - - high | 0..1 | Not Used | Quantity ( SimpleQuantity ) | High limit Constraint (qty-3): If a code for the unit is present, the system SHALL also be present Constraint (sqty-1): The comparator is not used on a SimpleQuantity |
|||
- - - - value | 0..1 | Not Used | Decimal | Numerical value (with implicit precision) | |||
- - - - unit | 0..1 | Not Used | String | Unit representation | |||
- - - - system | 0..1 | Not Used | Uri | System that defines coded unit form | |||
- - - - code | 0..1 | Not Used | Code | Coded form of the unit | |||
- - text | 0..1 | Not Used | String | Text based reference range in an observation | |||
- related | 0..* | Not Used | BackboneElement | Resource related to this observation | |||
- - modifierExtension | 0..* | Not Used | Extension | Extensions that cannot be ignored Constraint (ext-1): Must have either extensions or value[x], not both |
|||
- - type | 0..1 | Not Used | Code | has-member : derived-from : sequel-to : replaces : qualified-by : interfered-by Binding (required): Codes specifying how two observations are related. ObservationRelationshipType |
|||
- - target | 1..1 | Not Used | Reference | Resource that is related to this one Constraint (ref-1): SHALL have a contained resource if a local reference is provided |
|||
Not Used | QuestionnaireResponse | ||||||
Not Used | Sequence | ||||||
Not Used | CareConnect-Observation-1 | ||||||
- - - reference | 0..1 | Not Used | String | Literal reference, Relative, internal or absolute URL | |||
- - - identifier | 0..1 | Not Used | Identifier | Logical reference, when literal reference is not known | |||
- - - display | 0..1 | Not Used | String | Text alternative for the resource | |||
- component | 0..* | Required | BackboneElement | Used when reporting systolic and diastolic blood pressure. Slicing: Discriminator: code, Ordering: false, Rules: Open |
|||
- - code | 1..1 | Mandatory | CodeableConcept | Type of component observation (code / type) Slice discriminator: Code Binding (extensible): Codes identifying names of simple observations. ( http://hl7.org/fhir/stu3/valueset-observation-vitalsignresult.html ) |
|||
- - - coding | 0..* | Not Used | Coding | Code defined by a terminology system | |||
- - - - system | 1..1 | Mandatory | Uri | Identity of the terminology system Fixed Value: http://loinc.org |
|||
- - - - code | 1..1 | Mandatory | Code | Symbol in syntax defined by the system Binding (extensible): http://hl7.org/fhir/stu3/valueset-observation-vitalsignresult.html |
|||
- - - - display | 0..1 | Not Used | String | Representation defined by the system | |||
- - - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - - -text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- - valueQuantity | 0..1 | Not Used | Quantity | Actual component result Constraint (qty-3): If a code for the unit is present, the system SHALL also be present Binding (required): A value set describing common UCUM units for recording vital signs (http://hl7.org/fhir/stu3/valueset-ucum-vitals-common.html ) |
|||
- - - value | 1..1 | Not Used | Decimal | Numerical value (with implicit precision) | |||
- - - comparator | 0..1 | Not Used | Code | < | <= | >= | > - how to understand the value Binding (required): How the Quantity should be understood and represented. (http://hl7.org/fhir/stu3/valueset-quantity-comparator.html ) |
- - - unit | 1..1 | Not Used | String | Unit representation | |||
- - - system | 1..1 | Not Used | Uri | System that defines the Unified Code for Units of Measure (UCUM). Fixed Value: http://unitsofmeasure.org |
|||
- - - code | 1..1 | Not Used | Code | Coded responses from the common UCUM units for vital signs value set. Binding (required): A value set for common UCUM units for recording vital signs (http://hl7.org/fhir/stu3/valueset-ucum-vitals-common.html ) |
|||
- - dataAbsentReason | 0..1 | Not Used | CodeableConcept | Why the component result is missing Binding (extensible): Codes specifying why the result (Observation.value[x]) is missing. (http://hl7.org/fhir/stu3/valueset-observation-valueabsentreason.html ) |
|||
- - - coding | 0..* | Not Used | Coding | Code defined by a terminology system | |||
- - - - system | 0..1 | Not Used | Uri | Identity of the terminology system | |||
- - - - version | 0..1 | Not Used | String | Version of the system - if relevant | |||
- - - - code | 0..1 | Not Used | Code | Symbol in syntax defined by the system | |||
- - - - display | 0..1 | Not Used | String | Representation defined by the system | |||
- - - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- component (systolicComponent) | 0..* | Required | BackboneElement | Component results | |||
- -modifierExtension | 0..* | Not Used | Extension | Extensions that cannot be ignored Constraint (ext-1): Must have either extensions or value[x], not both |
|||
- - code | 1..1 | Mandatory | CodeableConcept | Type of component observation (code / type) Binding (extensible): This value set indicates the allowed vital sign result types. (http://hl7.org/fhir/stu3/valueset-observation-vitalsignresult.html ) |
|||
- - - coding | 0..* | Required | Coding | Code defined by a terminology system Slicing: Discriminator: code, Ordering: false, Rules: Open |
|||
- - - coding (loinc) | 1..1 | Mandatory | Coding | Systolic Blood Pressure | |||
- - - - system | 1..1 | Mandatory | Uri | Identity of the terminology system Fixed Value: http://loinc.org |
|||
- - - - version | 0..1 | Not Used | String | Version of the system - if relevant | |||
- - - - code | 1..1 | Not Used | Code | Symbol in syntax defined by the system Fixed Value: 8480-6 |
|||
- - - - display | 0..1 | Not Used | String | Representation defined by the system | |||
- - - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - - coding (snomedCT) | 1..1 | Mandatory | Coding | Systolic Blood Pressure | |||
- - - - extension (snomedCTDescriptionID) | 0..1 | Not Used | Extension | The SNOMED CT Description ID for the display. Constraint (ext-1): Must have either extensions or value[x], not both URL: https://fhir.hl7.org.uk/STU3/StructureDefinition/Extension-coding-sctdescid |
|||
- - - - system | 1..1 | Mandatory | Uri | Identity of the terminology system Fixed Value: http://snomed.info/sct |
|||
- - - - code | 1..1 | Mandatory | Code | Symbol in syntax defined by the system Fixed Value: 72313002 |
|||
- - - - display | 1..1 | Mandatory | String | Representation defined by the system Fixed Value: Systolic arterial pressure |
|||
- - - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- - valueQuantity | 0..1 | Not Used | Quantity | Vital Sign Value recorded with UCUM Constraint (qty-3): If a code for the unit is present, the system SHALL also be present Binding (required): A value set describing common UCUM units for recording vital signs (http://hl7.org/fhir/stu3/valueset-ucum-vitals-common.html ) |
|||
- - - value | 1..1 | Mandatory | Decimal | Numerical value (with implicit precision) | |||
- - - comparator | 0..1 | Not Used | Code | <\ | <= | >= | > - how to understand the value Binding (required): How the Quantity should be understood and represented. (http://hl7.org/fhir/stu3/valueset-quantity-comparator.html ) |
||
- - - unit | 1..1 | Mandatory | String | Unit representation | |||
- - - system | 1..1 | Mandatory | Uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
|||
- - - code | 1..1 | Mandatory | Code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] |
|||
- - dataAbsentReason | 0..1 | Not Used | CodeableConcept | Why the component result is missing Binding (extensible): Codes specifying why the result (Observation.value[x]) is missing. (http://hl7.org/fhir/stu3/valueset-observation-valueabsentreason.html ) |
|||
- - - coding | 0..* | Not Used | Coding | Code defined by a terminology system | |||
- - - - system | 0..1 | Not Used | Uri | Identity of the terminology system | |||
- - - - version | 0..1 | Not Used | String | Version of the system - if relevant | |||
- - - - code | 0..1 | Not Used | Code | Symbol in syntax defined by the system | |||
- - - - display | 0..1 | Not Used | String | Representation defined by the system | |||
- - - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- - interpretation | 0..1 | Not Used | CodeableConcept | High, low, normal, etc. Binding (extensible): Codes identifying interpretations of observations. ( http://hl7.org/fhir/stu3/valueset-observation-interpretation.html ) |
|||
- - - coding | 0..* | Not Used | Coding | Code defined by a terminology system | |||
- - - - system | 0..1 | Not Used | Uri | Identity of the terminology system | |||
- - - - version | 0..1 | Not Used | String | Version of the system - if relevant | |||
- - - - code | 0..1 | Not Used | Code | Symbol in syntax defined by the system | |||
- - - - display | 0..1 | Not Used | String | Representation defined by the system | |||
- - - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- - referenceRange | 0..* | Not Used | see Observation.referenceRange | Provides guide for interpretation of component result | |||
- - component (diastolicComponent) | 0..* | Required | BackboneElement | Component results | |||
- - modifierExtension | 0..* | Not Used | Extension | Extensions that cannot be ignored Constraint (ext-1): Must have either extensions or value[x], not both |
|||
- - code | 1..1 | Mandatory | CodeableConcept | Type of component observation (code / type) Binding (example): Codes identifying names of simple observations. ( http://hl7.org/fhir/stu3/valueset-observation-codes.html ) |
|||
- - - coding | 0..* | Required | Coding | Code defined by a terminology system Slicing: Discriminator: code, Ordering: false, Rules: Open |
|||
- - - coding (loinc) | 1..1 | Mandatory | Coding | Diastolic Blood Pressure | |||
- - - - system | 1..1 | Mandatory | Uri | Identity of the terminology system Fixed Value: http://loinc.org |
|||
- - - - version | 0..1 | Not Used | String | Version of the system - if relevant | |||
- - - - code | 1..1 | Mandatory | Code | Symbol in syntax defined by the system Fixed Value: 8462-4 |
|||
- - - - display | 0..1 | Not Used | String | Representation defined by the system | |||
- - - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - - coding (snomedCT) | 1..1 | Mandatory | Coding | Diastolic Blood Pressure | |||
- - - - extension (snomedCTDescriptionID) | 0..1 | Not Used | Extension | The SNOMED CT Description ID for the display. Constraint (ext-1): Must have either extensions or value[x], not both URL: https://fhir.hl7.org.uk/STU3/StructureDefinition/Extension-coding-sctdescid |
|||
- - - - system | 1..1 | Mandatory | Uri | Identity of the terminology system Fixed Value: http://snomed.info/sct |
|||
- - - - code | 1..1 | Mandatory | Code | Symbol in syntax defined by the system Fixed Value: 1091811000000102 |
|||
- - - - display | 1..1 | Mandatory | String | Representation defined by the system Fixed Value: Diastolic arterial pressure |
|||
- - - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- - valueQuantity | 0..1 | Not Used | Quantity | Vital Sign Value recorded with UCUM Constraint (qty-3): If a code for the unit is present, the system SHALL also be present Binding (required): A value set describing common UCUM units for recording vital signs (http://hl7.org/fhir/stu3/valueset-ucum-vitals-common.html ) |
|||
- - - value | 1..1 | Mandatory | Decimal | Numerical value (with implicit precision) | |||
- - - comparator | 0..1 | Not Used | Code | < | <= | >= | > - how to understand the value Binding (required): How the Quantity should be understood and represented. (http://hl7.org/fhir/stu3/valueset-quantity-comparator.html ) |
|||
- - - unit | 1..1 | Mandatory | String | Unit representation | |||
- - - system | 1..1 | Mandatory | Uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
|||
- - - code | 1..1 | Mandatory | Code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] |
|||
- - dataAbsentReason | 0..1 | Not Used | CodeableConcept | Why the component result is missing Binding (extensible): Codes specifying why the result (Observation.value[x]) is missing. (http://hl7.org/fhir/stu3/valueset-observation-valueabsentreason.html ) |
|||
- - - coding | 0..* | Not Used | Coding | Code defined by a terminology system | |||
- - - - system | 0..1 | Not Used | Uri | Identity of the terminology system | |||
- - - - version | 0..1 | Not Used | String | Version of the system - if relevant | |||
- - - - code | 0..1 | Not Used | Code | Symbol in syntax defined by the system | |||
- - - - display | 0..1 | Not Used | String | Representation defined by the system | |||
- - - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- - interpretation | 0..1 | Not Used | CodeableConcept | High, low, normal, etc. Binding (extensible): Codes identifying interpretations of observations. ( http://hl7.org/fhir/stu3/valueset-observation-interpretation.html ) |
|||
- - - coding | 0..* | Not Used | Coding | Code defined by a terminology system | |||
- - - - system | 0..1 | Not Used | Uri | Identity of the terminology system | |||
- - - - version | 0..1 | Not Used | String | Version of the system - if relevant | |||
- - - - code | 0..1 | Not Used | Code | Symbol in syntax defined by the system | |||
- - - - display | 0..1 | Not Used | String | Representation defined by the system | |||
- - - - userSelected | 0..1 | Not Used | Boolean | If this coding was chosen directly by the user | |||
- - - text | 0..1 | Not Used | String | Plain text representation of the concept | |||
- - referenceRange | 0..* | Not Used | see Observation.referenceRange | Prov |