DDS-Report-Device-1
Device | |
Definition | |
Control | 0..* |
Type | Device |
Comments | |
Device.id | |
Definition |
The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. |
Control | 0..1 ? |
Type | Id |
Comments |
The only time that a resource does not have an id is when it is being submitted to the server using a create operation. Bundles always have an id, though it is usually a generated UUID. |
Device.meta | |
Definition |
The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content may not always be associated with version changes to the resource. |
Control | 0..1 ? |
Type | Meta |
Comments | |
Device.implicitRules | |
Definition |
A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. |
Control | 0..1 ? |
Type | Uri |
Is Modifier | True |
Comments |
Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element as much as possible. |
Device.language | |
Definition |
The base language in which the resource is written. |
Control | 0..1 ? |
Binding |
A human language. The codes SHALL be taken from http://tools.ietf.org/html/bcp47 |
Type | Code |
Comments |
Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). |
Device.text | |
Definition |
A human-readable narrative that contains a summary of the resource, and may be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety. |
Control | 0..1 ? |
Type | Narrative |
Aliases | narrative, html, xhtml, display |
Comments |
Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. |
Device.contained | |
Definition | |
Control | 0..* |
Type | Resource |
Comments | |
Device.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the resource. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.modifierExtension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the resource, and that modifies the understanding of the element that contains it. Usually modifier elements provide negation or qualification. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. |
Control | 0..* ? |
Type | Extension |
Is Modifier | True |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.identifier | |
Definition |
Unique instance identifiers assigned to a device by organizations like manufacturers or owners. If the identifier identifies the type of device, Device.type should be used. |
Control | 0..* ? |
Type | Identifier |
Comments |
Often fixed to the device as a barcode and may include names given to the device in local usage. Note that some of the barcodes affixed to the device identify its type, not its instance. For the FDA mandated Unique Device Identifier (UDI) use the Device.udi element. |
Device.identifier.id | |
Definition |
unique id for the element within a resource (for internal references). |
Control | 0..1 ? |
Type | Id |
Comments |
RFC 4122 |
Device.identifier.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.identifier.use | |
Definition |
The purpose of this identifier. |
Control | 0..1 ? |
Binding |
Identifies the purpose for this identifier, if known . The codes SHALL be taken from http://hl7.org/fhir/ValueSet/identifier-use |
Type | Code |
Is Modifier | True |
Requirements |
Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. |
Comments |
This is labeled as "Is Modifier" because applications should not mistake a temporary id for a permanent one. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. |
Device.identifier.type | |
Definition |
A coded type for the identifier that can be used to determine which identifier to use for a specific purpose. |
Control | 0..1 ? |
Binding |
A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. The codes SHALL be taken from the following if appropriate, otherwise an alternate coding may be included instead. http://hl7.org/fhir/ValueSet/identifier-type |
Type | CodeableConcept |
Requirements |
Allows users to make use of identifiers when the identifier system is not known. |
Comments |
This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. |
Device.identifier.type.id | |
Definition |
unique id for the element within a resource (for internal references). |
Control | 0..1 ? |
Type | Id |
Comments |
RFC 4122 |
Device.identifier.type.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.identifier.type.coding | |
Definition |
A reference to a code defined by a terminology system. |
Control | 0..* ? |
Type | Coding |
Requirements |
Allows for translations and alternate encodings within a code system. Also supports communication of the same instance to systems requiring different encodings. |
Comments |
Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labelled as UserSelected = true. |
Device.identifier.type.coding.id | |
Definition |
unique id for the element within a resource (for internal references). |
Control | 0..1 ? |
Type | Id |
Comments |
RFC 4122 |
Device.identifier.type.coding.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.identifier.type.coding.system | |
Definition | |
Control | 1..* |
Comments | |
Example | http://hl7.org/fhir/ValueSet/identifier-type |
Device.identifier.type.coding.version | |
Definition |
The version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured. and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. |
Control | 0..1 ? |
Type | String |
Comments |
Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. |
Device.identifier.type.coding.code | |
Definition | |
Control | 1..* |
Comments | |
Example | SNO |
Device.identifier.type.coding.display | |
Definition | |
Control | 1..* |
Comments | |
Example | Serial Number |
Device.identifier.type.coding.userSelected | |
Definition |
Indicates that this coding was chosen by a user directly - i.e. off a pick list of available items (codes or displays). |
Control | 0..1 ? |
Type | Boolean |
Requirements |
This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. |
Comments |
Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. |
Device.identifier.type.text | |
Definition |
A human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. |
Control | 0..1 ? |
Type | String |
Requirements |
The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. |
Comments |
Very often the text is the same as a displayName of one of the codings. |
Device.identifier.system | |
Definition | |
Control | 1..* |
Comments | |
Example | http://acme.com/devices/pacemakers/octane/serial |
Device.identifier.value | |
Definition | |
Control | 1..* |
Comments | |
Example | 1234-5678-90AB-CDEF |
Device.identifier.period | |
Definition |
Time period during which identifier is/was valid for use. |
Control | 0..1 ? |
Type | Period |
Comments |
This is not a duration - that's a measure of time (a separate type), but a duration that occurs at a fixed value of time. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). If duration is required, specify the type as Interval|Duration. |
Device.identifier.period.id | |
Definition |
unique id for the element within a resource (for internal references). |
Control | 0..1 ? |
Type | Id |
Comments |
RFC 4122 |
Device.identifier.period.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.identifier.period.start | |
Definition | |
Control | 1..* |
Comments | |
Device.identifier.period.end | |
Definition |
The end of the period. If the end of the period is missing, it means that the period is ongoing. The start may be in the past, and the end date in the future, which means that period is expected/planned to end at that time. |
Control | 0..1 ? |
Type | DateTime |
Comments |
The high value includes any matching date/time. i.e. 2012-02-03T10:00:00 is in a period that has a end value of 2012-02-03. |
Device.identifier.assigner | |
Definition | |
Control | 0..* |
Type | https://fhir.hl7.org.uk/StructureDefinition/CareConnect-Organization-1 |
Comments | |
Device.identifier.assigner.id | |
Definition |
unique id for the element within a resource (for internal references). |
Control | 0..1 ? |
Type | Id |
Comments |
RFC 4122 |
Device.identifier.assigner.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.identifier.assigner.reference | |
Definition | |
Control | 1..* |
Comments | |
Device.identifier.assigner.display | |
Definition |
Plain text narrative that identifies the resource in addition to the resource reference. |
Control | 0..1 ? |
Type | String |
Comments |
This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. |
Device.type | |
Definition | |
Control | 0..* |
Binding |
The codes SHOULD be taken from http://acme.com/devices ; other codes may be used where these codes are not suitable |
Comments | |
Device.type.id | |
Definition |
unique id for the element within a resource (for internal references). |
Control | 0..1 ? |
Type | Id |
Comments |
RFC 4122 |
Device.type.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.type.coding | |
Definition | |
Control | 0..1 |
Comments | |
Device.type.coding.id | |
Definition |
unique id for the element within a resource (for internal references). |
Control | 0..1 ? |
Type | Id |
Comments |
RFC 4122 |
Device.type.coding.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.type.coding.system | |
Definition | |
Control | 1..* |
Comments | |
Example | http://acme.com/devices |
Device.type.coding.version | |
Definition |
The version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured. and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. |
Control | 0..1 ? |
Type | String |
Comments |
Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. |
Device.type.coding.code | |
Definition | |
Control | 1..* |
Comments | |
Example | octane2014 |
Device.type.coding.display | |
Definition | |
Control | 1..* |
Comments | |
Example | Performance pace maker for high octane patients |
Device.type.coding.userSelected | |
Definition |
Indicates that this coding was chosen by a user directly - i.e. off a pick list of available items (codes or displays). |
Control | 0..1 ? |
Type | Boolean |
Requirements |
This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. |
Comments |
Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. |
Device.type.text | |
Definition |
A human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. |
Control | 0..1 ? |
Type | String |
Requirements |
The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. |
Comments |
Very often the text is the same as a displayName of one of the codings. |
Device.note | |
Definition |
Descriptive information, usage information or implantation information that is not captured in an existing element. |
Control | 0..* ? |
Type | Annotation |
Comments |
For systems that do not have structured annotations, they can simply communicate a single annotation with no author or time. This element may need to be included in narrative because of the potential for modifying information. Annotations SHOULD NOT be used to communicate "modifying" information that could be computable. (This is a SHOULD because enforcing user behavior is nearly impossible). |
Device.note.id | |
Definition |
unique id for the element within a resource (for internal references). |
Control | 0..1 ? |
Type | Id |
Comments |
RFC 4122 |
Device.note.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.note.author[x] | |
Definition |
The individual responsible for making the annotation. |
Control | 0..1 ? |
Type | Choice of: |
Comments | |
Device.note.time | |
Definition |
Indicates when this particular annotation was made. |
Control | 0..1 ? |
Type | DateTime |
Comments | |
Device.note.text | |
Definition |
The text of the annotation. |
Control | 1..1 ? |
Type | String |
Comments |
Note that FHIR strings may not exceed 1MB in size |
Device.status | |
Definition |
Status of the Device availability. |
Control | 0..1 ? |
Binding |
The availability status of the device. The codes SHALL be taken from http://hl7.org/fhir/ValueSet/devicestatus |
Type | Code |
Is Modifier | True |
Comments |
Note that FHIR strings may not exceed 1MB in size |
Device.manufacturer | |
Definition | |
Control | 0..* |
Comments | |
Example | Acme Devices, Inc |
Device.model | |
Definition | |
Control | 0..* |
Comments | |
Example | PM/Octane 2014 |
Device.version | |
Definition |
The version of the device, if the device has multiple releases under the same model, or if the device is software or carries firmware. |
Control | 0..1 ? |
Type | String |
Comments |
Note that FHIR strings may not exceed 1MB in size |
Device.manufactureDate | |
Definition |
The date and time when the device was manufactured. |
Control | 0..1 ? |
Type | DateTime |
Comments | |
Device.expiry | |
Definition |
The date and time beyond which this device is no longer valid or should not be used (if applicable). |
Control | 0..1 ? |
Type | DateTime |
Comments | |
Device.udi | |
Definition |
United States Food and Drug Administration mandated Unique Device Identifier (UDI). Use the human readable information (the content that the user sees, which is sometimes different to the exact syntax represented in the barcode) - see http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/UniqueDeviceIdentification/default.htm. |
Control | 0..1 ? |
Type | String |
Comments |
The unique identifier may identify an instance of a device uniquely, or it may only identify the type of the device. A portion of the UDI - the DI part - can be extracted from the UDI when required, and used to look up information about the device through the GUDID. |
Device.lotNumber | |
Definition | |
Control | 0..* |
Comments | |
Example | 1234-5678 |
Device.owner | |
Definition | |
Control | 0..* |
Type | https://fhir.hl7.org.uk/StructureDefinition/CareConnect-Organization-1 |
Comments | |
Device.owner.id | |
Definition |
unique id for the element within a resource (for internal references). |
Control | 0..1 ? |
Type | Id |
Comments |
RFC 4122 |
Device.owner.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.owner.reference | |
Definition | |
Control | 1..* |
Comments | |
Device.owner.display | |
Definition |
Plain text narrative that identifies the resource in addition to the resource reference. |
Control | 0..1 ? |
Type | String |
Comments |
This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. |
Device.location | |
Definition | |
Control | 0..* |
Type | Location |
Comments | |
Device.location.id | |
Definition |
unique id for the element within a resource (for internal references). |
Control | 0..1 ? |
Type | Id |
Comments |
RFC 4122 |
Device.location.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.location.reference | |
Definition | |
Control | 1..* |
Comments | |
Device.location.display | |
Definition |
Plain text narrative that identifies the resource in addition to the resource reference. |
Control | 0..1 ? |
Type | String |
Comments |
This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. |
Device.patient | |
Definition | |
Control | 0..* |
Type | Patient |
Comments | |
Device.patient.id | |
Definition |
unique id for the element within a resource (for internal references). |
Control | 0..1 ? |
Type | Id |
Comments |
RFC 4122 |
Device.patient.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.patient.reference | |
Definition | |
Control | 1..* |
Comments | |
Device.patient.display | |
Definition |
Plain text narrative that identifies the resource in addition to the resource reference. |
Control | 0..1 ? |
Type | String |
Comments |
This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. |
Device.contact | |
Definition |
Contact details for an organization or a particular human that is responsible for the device. |
Control | 0..* ? |
Type | ContactPoint |
Comments |
used for troubleshooting etc. |
Device.contact.id | |
Definition |
unique id for the element within a resource (for internal references). |
Control | 0..1 ? |
Type | Id |
Comments |
RFC 4122 |
Device.contact.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.contact.system | |
Definition | |
Control | 1..* |
Comments | |
Example | phone |
Device.contact.value | |
Definition | |
Control | 1..* |
Comments | |
Example | ext 4352 |
Device.contact.use | |
Definition |
Identifies the purpose for the contact point. |
Control | 0..1 ? |
Binding |
Use of contact point The codes SHALL be taken from http://hl7.org/fhir/ValueSet/contact-point-use |
Type | Code |
Is Modifier | True |
Requirements |
Need to track the way a person uses this contact, so a user can choose which is appropriate for their purpose. |
Comments |
This is labeled as "Is Modifier" because applications should not mistake a temporary or old contact etc.for a current/permanent one. Applications can assume that a contact is current unless it explicitly says that it is temporary or old. |
Device.contact.rank | |
Definition |
Specifies a preferred order in which to use a set of contacts. Contacts are ranked with lower values coming before higher values. |
Control | 0..1 ? |
Type | PositiveInt |
Comments |
Note that rank does not necessarily follow the order in which the contacts are represented in the instance. |
Device.contact.period | |
Definition |
Time period when the contact point was/is in use. |
Control | 0..1 ? |
Type | Period |
Comments |
This is not a duration - that's a measure of time (a separate type), but a duration that occurs at a fixed value of time. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). If duration is required, specify the type as Interval|Duration. |
Device.contact.period.id | |
Definition |
unique id for the element within a resource (for internal references). |
Control | 0..1 ? |
Type | Id |
Comments |
RFC 4122 |
Device.contact.period.extension | |
Definition |
May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* ? |
Type | Extension |
Aliases | extensions, user content |
Comments |
There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Device.contact.period.start | |
Definition | |
Control | 1..* |
Comments | |
Device.contact.period.end | |
Definition |
The end of the period. If the end of the period is missing, it means that the period is ongoing. The start may be in the past, and the end date in the future, which means that period is expected/planned to end at that time. |
Control | 0..1 ? |
Type | DateTime |
Comments |
The high value includes any matching date/time. i.e. 2012-02-03T10:00:00 is in a period that has a end value of 2012-02-03. |
Device.url | |
Definition |
A network address on which the device may be contacted directly. |
Control | 0..1 ? |
Type | Uri |
Comments |