Guidance for populating the NEWS2 Oxygen Saturation Observation.

The NEWS2 oxygen saturation observation reading uses the CareConnect-OxygenSaturation-Observation-1 profile.

Guidance for Populating a NEWS2 Oxygen Saturation Observation

Note that some elements are “Left uncurated as no use case in NEWS2”, and are not needed for NEWS2.

CareConnect-OxygenSaturation-Observation-1 elementPopulation Guidance
identifierA unique identifier assigned to this observation (such as a generated Universally Unique Identifier {UUID})
basedOnLeft uncurated as no use case in NEWS2
statusFixed to "final"
categoryThe code is fixed to "vital-signs"
The system is fixed to "http://hl7.org/fhir/observation-category"
codeThe code MUST contain the Magic Code as per the HL7 vital signs guidance, MUST also have a SNOMED CT equivalent Magic Code and MAY have a more refined SNOMED CT concept code

For NEWS2 Oxygen Saturation Magic Code, the code is fixed to "59408-5" and the system is fixed to "http://loinc.org"

For NEWS2 oxygen saturation SNOMED CT Magic Code, the code is fixed to "103228002" and the system is fixed to "http://snomed.info/sct"

For more refined SNOMED CT codes, the code is from the valueSet defined here and the system is fixed to "http://snomed.info/sct"

If a more refined SNOMED CT code is used, then the userSelected element for that code MUST be checked.
subjectA link to the Patient
contextLeft uncurated as no use case in NEWS2
effective[x]The date and time that the oxygen saturation was taken, using effectiveDateTime
issuedLeft uncurated as no use case in NEWS2
performerA link to the performer who carried out this observation. This must be a qualified practitioner and associated organization
value[x]The actual oxygen saturation reading as a valueQuantity. The unit is fixed to "%" and the system fixed to UCUM "http://unitsofmeasure.org"
dataAbsentReasonLeft uncurated as no use case in NEWS2 (as only observations with values should be sent for NEWS2)
interpretationLeft uncurated as no use case in NEWS2
commentAny additional notes or actions that the performer wishes to convey
bodySiteLeft uncurated as no use case in NEWS2. Body site information may be implied by the pre-coordinated SNOMED CT concept used in Observation.code
methodLeft uncurated as no use case in NEWS2
deviceLeft uncurated as no use case in NEWS2
referenceRangeLeft uncurated as no use case in NEWS2
relatedA link to any related observations
componentNone of the component elements are required for NEWS2 Pulse rate Observation

More Refined SNOMED CT Codes for Oxygen Saturation

«103228002|Hemoglobin saturation with oxygen (observable entity)|
MINUS («442349007|Venous oxygen saturation (observable entity)|
OR «927981000000106|Baseline oxygen saturation at periphery (observable entity)|
OR «852651000000100|Maximum peripheral oxygen saturation (observable entity)|
OR «852661000000102|Minimum peripheral oxygen saturation (observable entity)|
OR «852641000000103|Target peripheral oxygen saturation (observable entity)|)